Temporal transforms

Root transforms creates new time-varying signals from bound numeric signals or expressions. Rules, calculations, and later transforms can reference the new names. Supported operations cover rolling statistics and rates of change, using CAN logs, decoded CSV, or memory inputs; the feature is not specific to current.

Start with one rolling mean

Download the minimal configuration, meter.asc, and meter.dbc into one directory. Synthetic readings include 10 A at 0 s, 20 A at 0.12 s, 40 A at 0.30 s, then 5 A at 0.42 and 0.60 s. The configuration contains one rolling_time_mean and one select, using default actual time. Omitted validity is three times the DBC's 100 ms period.

yaml
config_version: 4                 # Current analysis configuration version
dataset:                          # Analysis identity and optional input range
  name: rolling_actual            # Name used to identify and reference this object
sources:                          # Input sources used by this analysis
  - paths: meter.asc              # File, continuous file list or directory; relative to this configuration
    dbc_by_channel:               # DBC files indexed by user-facing CAN channel
      '1': meter.dbc              # DBC for channel 1; channel keys are strings
signals:                          # Signals available to expressions
  - name: current                 # Name used to identify and reference this object
    field:                        # Locate the original input field
      frame_id: 0x100             # CAN message identifier; decimal or prefixed hexadecimal/binary
      signal: Current             # Exact signal name defined in the DBC
transforms:                       # Time-window calculations producing output signals
  - name: average                 # Name used to identify and reference this object
    operation: rolling_time_mean  # Calculation to apply to the expression
    expr: current                 # Formula using the declared signal or derived names
    window: 0.1s                  # Length of the trailing calculation window
    step: 0.1s                    # Spacing between output times
calculations:                     # Requested statistics or selected rows
  - name: average_rows            # Name used to identify and reference this object
    operation: select             # Calculation to apply to the expression
    expr: average                 # Formula using the declared signal or derived names
execution:                        # Execution settings for this analysis
  process_count: 4                # At most four workers; this one-file example uses one
powershell
chronaxis validate rolling-actual.yaml
chronaxis run rolling-actual.yaml --output rolling-result

Find the selection table through this run's manifest. At 0.20 s, average_rows should be 18 A: in [0.10,0.20), 10 A lasts 0.02 s and 20 A lasts 0.08 s, so (10×0.02+20×0.08)/0.1=18. Under default strict policy, an initial window without enough history has no value.

Fields and operation matrix

Fields belong to transforms[]. A plan allows at most 64 transforms. Names must be unique across source signals, derived signals, and transforms; circular references are rejected. A transform unused by requested results is not calculated.

Field Type, requirement, and default Meaning
name Required valid name New time-varying signal referenced by later expr or condition
operation Required string An operation below or a host-registered temporal operator
expr Required numeric expression float64/int64/uint64 input, not bool or enum
window Required positive duration for grid operations Lookback width under the selected interval basis
step Required positive duration for grid operations Actual-time spacing between output points
origin Optional coordinate for grids; defaults to timebase zero Output times origin+n×step; use a compatible date/time for absolute sources
max_gap Required positive duration for adjacent_rate Maximum actual-time gap between measured updates
unit Optional compatible unit Output unit, otherwise derived from the operation
partial_policy Grid-only option; default strict strict requires complete data; report allows supported partial values with quality
minimum_coverage Grid-only finite number; default 0 Inclusive 0–1 required valid-data proportion; does not invent missing data
interval Optional object; inherits intervals.default, normally actual actual uses elapsed time; fixed/dbc advance with driver updates; see intervals
operation window and step origin / partial_policy / minimum_coverage max_gap Result
rolling_time_mean Required Optional Forbidden Duration-weighted mean in the lookback window
rolling_minimum, rolling_maximum Required Optional Forbidden Extrema of held values with positive duration
rolling_integral Required Optional Forbidden Integral of valid held values in the window
adjacent_rate Forbidden All forbidden Required Difference between current and previous measured values divided by the corresponding interval; output at the right measurement
window_rate Required Optional Forbidden Difference between valid window endpoints divided by window width
sample_fit_slope Required Optional Forbidden Equal-weight straight-line fit of real updates; at least two distinct positions

Rolling means, integrals, and rates return float64. Rolling extrema retain the numeric input type when conversion permits. Convert absolute Celsius to K before integration; temperature rates use difference-per-time units. Record timestamps and valid_for always use actual time; fixed periods do not restore expired samples.

Extended example: seven transforms and a DBC period

The following example uses the same records and adds seven transforms, DBC-period weighting, and individual selections. Its small batch setting demonstrates resource controls and is not necessary for the minimal task.

The ASC contains 10, 20, 40, 5 and 5 A at 0.00, 0.12, 0.30, 0.42 and 0.60 s. The DBC specifies a 100 ms frame period. At 0.20 s there is no new frame, but the analysis can still ask for the average current over one frame period. Download the configuration, ASC and DBC into the same directory.

Run and read the example

powershell
python -m chronaxis validate analysis.yaml
python -m chronaxis run analysis.yaml --backend numpy --work-dir work-grid --output result-grid

To compare the reference backend, use --backend reference with a separate work directory, such as --work-dir work-grid-reference. The output directory can be reused; each run creates timestamped results. The input alias current refers to Current in channel 1, standard frame 0x100. Each entry under transforms names a new series available to rule conditions, calculations or later transforms. This example uses select to expose its actual output timestamps.

Selection Actual time Expected value Meaning
average_rows 0.20 s 130/9 ≈ 14.444444 A Mean over one selected frame period
low_rows / high_rows 0.20 s 10 / 20 A Extrema of held values with positive duration
charge_rows 0.20 s 13/9 ≈ 1.444444 A·s Current integral, with unit label A*s
adjacent_rows 0.30 s 200 A/s Change between consecutive measurements divided by one period
endpoint_rows / fit_rows 0.30 s 150 / 150 A/s Endpoint change and equal-weight fitted slope over two periods

How to interpret the clock

Output times follow origin + n × step on the real clock. The default origin is zero on the analysis timebase. window sets the lookback width. interval selects actual time, a fixed period, or a verified DBC period for the window measure and rate denominator. A fixed interval looks like {mode: fixed, value: 0.1s, driver: current}. DBC mode requires an original CAN frame with a declared period.

For actual time, set intervals.default to {mode: actual}. The mean at 0.20 s uses [0.10,0.20) on the real clock and equals (0.02×10+0.08×20)/0.1 = 18 A. In the supplied DBC example, 0.12 to 0.30 s represents one period. At 0.20 s, 4/9 of that period has elapsed. The 10 A reading gets 5/9 of the weight and the 20 A reading gets 4/9. The later frame establishes that split. The calculated row retains its 0.20 s timestamp. After the last driver frame, an unfinished period has no inferred length.

Choose the rate that answers your question

  • adjacent_rate emits at the right-hand real input update. max_gap and source valid_for refer to actual elapsed time. An expired or unknown interval breaks the pair. For independent clocks, suppose driver frames arrive at 0 and 0.12 s and current is 1 A at 0.03 s and 7 A at 0.09 s. With a fixed period of 0.1 s the two readings span 0.05 selected seconds. After receiving the 0.12 s driver, the row at 0.09 s reports 120 A/s.
  • window_rate subtracts the held values at the two boundaries and divides by the selected window width. A real update at the right boundary supplies that boundary's value. Rolling means and integrals cover a half-open interval, so the update contributes no area to the preceding window.
  • sample_fit_slope fits equally weighted real input updates inside the window, including real samples at its boundaries. It needs at least two distinct positions. A clipped boundary adds no measurement. For 20°C at 0 s, 21°C at 1 s and 26°C at 3 s, the adjacent, three-second endpoint and fitted rates at 3 s are 2.5, 2 and approximately 2.071429 delta_K/s in actual mode. The window-change event rule window_delta checks whether the difference between the window endpoints meets a threshold. It does not divide that difference by elapsed duration, unlike the rate operations described here.

Warm-up and partial windows

The default partial_policy: strict requires a complete window. Early ticks, expired readings or too few fit samples can produce unknown values. With an explicit report policy and minimum_coverage, supported partial results use only observed valid weight. The mean divides by that weight, and the integral retains only the known area. Selected partial values carry ESTIMATED quality. Read a scalar result's status and quality together. An endpoint rate still needs both endpoints. Between ticks, output holds only within the observed range. A shorter grid step samples the series more often, but an excursion shorter than a step may still be missed.

Even with complete coverage of the preceding window, an estimated reading used in the endpoint rate or fitted slope makes the result estimated. With report, the result retains its value and estimated status. With strict, it has no numeric value.