On this pageComplete minimal and extended examplesPrepare sources and signalsCheck whether the charging preset matches your objectivePreset parameter referenceCharging periods: charge_session.parametersFault context: fault_context.parametersRequest/response: command_response.parametersThreshold alarms: threshold_excursion.parametersRole requirementsWhen to provide semantic declarationsPreset examplesRequest/response exampleThreshold alarms and total durationCharging activities and energy exampleFault-context window example

Presets

A preset is a predefined set of rules and calculations. For example, identify which signal represents a request and which represents a response, and a preset creates two rising-edge rules and a pairing definition. A role is a signal's purpose within that preset. role_bindings maps each role to a name already declared in signals.

Presets expand into derived, rules, windows, sequences, or calculations when the plan loads. Read results through those generated nodes. Prepare signals that meet the role requirements before selecting a preset.

Unless stated otherwise, examples use actual elapsed time. With fixed/DBC intervals, duration confirmation, waiting deadlines, change windows, and pairing delay_ns use the selected period. Original timestamps and signal expiry use actual time. See the duration comparison.

Each preset is an object in the root presets list. The table below is relative to presets[], for example presets[].name. parameters and role_bindings differ by preset type.

Field Type Required Default Meaning
name String Yes None Name this preset instance, for example cmd. Generated names use it as a prefix, such as cmd_request. It must be unique, and its generated names must not collide with existing rules, windows, or calculations. See naming conventions.
preset_type String Yes None charge_session: identify charging periods. fault_context: select context around fault onset. command_response: match requests and responses. threshold_excursion: identify threshold-alarm periods.
version String No "1" Preset definition version. Use the string "1", not number 1.
parameters Object Yes None Business parameters for this preset type, obtained from the analysis requirement or device protocol. Parameters from different types cannot be mixed.
role_bindings Object No, except for threshold presets {} Map each role to an original bound signal's signals[].name, for example request: start_button. Role requirements still apply.

Explicit role mappings are recommended. Except for threshold presets, an omitted role is resolved using declarations such as semantic_id. Exactly one signal must match. No match or multiple matches is an error; similar signal names are not a selection rule.

A role's requirements describe acceptable inputs: for example, charging current requires the expected type, unit, sign convention, and measurement location. These requirements are also called a semantic contract. Automatic resolution checks these declarations rather than guessing from CSV column names. An explicit mapping chooses the signal but does not waive its requirements.

Complete minimal and extended examples

These independent configurations use the included 0–4 s synthetic CAN input and contain all required sources, signals, and presets. Run chronaxis run filename.yaml --output new-directory.

Feature Minimal example Extended example Expected result
Charging periods preset-charge-minimal.yaml: mode 1 from 1–3 s, current 10 A preset-charge-energy.yaml: adds 400 V, energy, and charge integrals Activity [1,3); extended energy 8000/3600 Wh and charge 20/3600 Ah.
Fault context preset-fault-minimal.yaml: alarm rises at 1 s; select 1 s after preset-fault-context.yaml: select 1 s before and 2 s after; allow an initial alarm Minimal [1,2), extended [0,3). Initial false means enabling emit_initial adds no event here.
Request/response preset-command-minimal.yaml: request at 1 s, response at 2 s, explicit roles preset-command-automatic.yaml: semantic declarations replace explicit bindings Both produce one pair with a 1 s delay.
Threshold alarm preset-threshold-minimal.yaml: temperatures 70, 85, 77, 75, 70 at one-second intervals preset-threshold-delay.yaml: 500 ms entry and exit waits Minimal [1,3); extended [1.5,3.5). Both activities last 2 s.

Prepare sources and signals

The complete electrical-base.yaml uses synthetic ASC frames and a DBC and analyzes the observed range. Its relevant signal definitions are reproduced below for reference; do not insert them twice. Dedicated examples above have their own fixed expected results; conceptual timelines below need not all occur in the shared teaching input.

There is one CAN source, so the signals need no repeated source. IDs and signal names come from the DBC, which also supplies types and units. The explicit 20 s validity is for sparse teaching records, not a recommended device setting.

yaml
signals:                                 # Signals available to presets.
  - name: temperature                    # Name used by the threshold role.
    field:                               # Original CAN signal.
      frame_id: '0x11d'                  # Message ID from the DBC.
      signal: Temperature                # Case-sensitive DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
  - name: voltage                        # Voltage role candidate.
    field:                               # Original CAN signal.
      frame_id: '0x11f'                  # Message ID from the DBC.
      signal: Voltage                    # DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
    measurement_location: pack_terminal  # Actual measurement is at the pack terminals.
  - name: current                        # Current role candidate.
    field:                               # Original CAN signal.
      frame_id: '0x114'                  # Message ID from the DBC.
      signal: Current                    # DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
    measurement_location: pack_terminal  # Actual measurement location.
    sign_convention: positive_is_charge  # Positive values mean charging; no sign conversion.
  - name: mode                           # Integer operating-mode signal.
    field:                               # Original CAN signal.
      frame_id: '0x118'                  # Message ID from the DBC.
      signal: Mode                       # DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
  - name: request                        # Boolean request signal.
    field:                               # Original CAN signal.
      frame_id: '0x11a'                  # Message ID from the DBC.
      signal: Request                    # DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
    choices:                             # Input code to boolean value.
      - [0, false]
      - [1, true]
  - name: response                       # Boolean response signal.
    field:                               # Original CAN signal.
      frame_id: '0x11b'                  # Message ID from the DBC.
      signal: Response                   # DBC signal name.
    valid_for: 20s                       # Validity for this teaching input.
    choices:                             # Input code to boolean value.
      - [0, false]
      - [1, true]

Check whether the charging preset matches your objective

Version 1 of charge_session has a fixed combination: mode equals a specified integer, current is strictly greater than a threshold, and the condition lasts at least the specified duration. Once qualified, calculations include the entire interval from condition onset to end. Energy is in Wh; charge is in Ah. Use it when those semantics match your task.

Requirement Appropriate entry point
Specified mode, current > 5 A, duration >= 3 s, output Wh Charging preset, with verified current direction and measurement location.
Current >= 10 A, including exactly 10 A Sustained-condition rule plus event integral. The preset's > 10 excludes equality.
Duration strictly > 60 s Ordinary rule with minimum_duration: 60s and duration_comparison: ">"; do not approximate with 60.1 s.
Output kWh directly, or combine several custom state conditions Ordinary rule retaining the complete condition, plus an integral with unit: kWh.
Integrate an explicit voltage × current formula with no direction/location requirement Ordinary integral; it needs no extra semantic declarations merely to fit a preset.

In the energy example, mode is 1, current 10 A, and voltage 400 V during 1–3 s. Preset threshold 5 A and ordinary condition mode == 1 and current > 5 both select [1,3): 400 × 10 × 2 = 8000 J = 2.222222… Wh. With threshold 10 A, the preset finds no qualifying interval, while ordinary current >= 10 still selects it and can output 0.002222222… kWh. Those numbers have different units.

Ordinary rules also default to selection_origin: onset, including the qualifying wait. Explicit confirmed starts at confirmation instead. Choose a coverage requirement from the actual task; charging analysis does not automatically imply a 95% threshold.

Preset parameter reference

Charging periods: charge_session.parameters

Complete example.

charge_session is a preset_type value, not an additional parent key. These fields belong inside presets[].parameters.

Field Type Required Default Meaning
mode_value Integer Yes None Device mode code considered charging. It must fit the bound mode signal's integer type and valid range. Obtain it from the device's state-code definitions.
current_min Number Yes None Threshold in A; negative values are allowed. Current must be strictly greater, so exactly 5 A does not satisfy a threshold of 5.
minimum_duration Duration string Yes None Nonnegative continuous duration for matching mode and current. 3s confirms after three seconds, but the selected activity begins at the original onset.
compute_energy Boolean No false True generates voltage × current power and an energy integral in Wh, requiring the voltage role. False generates neither.
compute_charge Boolean No false True generates the current integral in Ah. Independent of compute_energy; either or both can be enabled.
minimum_coverage Number No 0 Inclusive range 0–1. For example, 0.9 requires 90% coverage. Any required coverage below the threshold marks coverage_status as indeterminate; this does not itself discard a computed value. See coverage.
partial_policy String No Inherits execution.partial_policy report keeps computable portions and marks incomplete data; strict returns null if required time is missing. Applies to the generated energy/charge calculations. See examples.

For instance name charge:

compute_energy compute_charge Generated nodes
false false charge_activity only.
true false Also charge_power and charge_energy in Wh.
false true Also charge_charge in Ah.
true true Activity, power, energy, and charge.

A different instance name changes the generated prefix.

Fault context: fault_context.parameters

Complete example.

These fields belong inside presets[].parameters, with preset_type: fault_context.

Field Type Required Default Meaning
pre Nonnegative duration string No 0s Context before fault onset. A fault at 10 s with 2s begins selection at 8 s.
post Nonnegative duration string No 0s Context after fault onset. At least one of pre/post must be positive. 3s in the example selects up to, but not including, 13 s.
emit_initial Boolean No false False does not treat an initially active alarm as a new fault. True emits an initial fault point and its context window.

The preset generates <name>_alarm as a rising-edge rule and <name>_context as a window. Windows from neighboring faults remain separate and are not automatically merged.

Request/response: command_response.parameters

Complete example.

These fields belong inside presets[].parameters, with preset_type: command_response.

Field Type Required Default Meaning
min_delay Nonnegative duration string No 0s Earliest allowed response delay. Zero permits response at the request timestamp.
max_delay Duration string Yes None Latest allowed response, not less than min_delay. A response exactly at the deadline succeeds.
emit_initial Boolean No false True permits an initial point independently for initially true request and response signals; false permits neither.
max_pending Positive integer No 65536 Maximum simultaneous pending requests. Exceeding it raises an error rather than dropping the oldest request. Choose it from expected concurrency and resource budgets.

Generated nodes are <name>_request, <name>_response, and <name>_pair. See sequences for queuing, missing data, and timeout behavior.

Threshold alarms: threshold_excursion.parameters

Complete example.

These fields belong inside presets[].parameters, with preset_type: threshold_excursion.

Field Type Required Default Meaning
unit String No Bound signal's unit Threshold unit; it must exactly match the signal unit. Usually omit it for a signal already declared in degC.
enter_threshold Number Yes None Enter when the value is at least this threshold. Must be greater than exit_threshold, for example 80.
exit_threshold Number Yes None Clear when the value is at most this threshold, for example 75. Between 75 and 80, retain known state.
enter_delay Nonnegative duration string No 0ns Continuous entry-condition wait; zero confirms immediately.
exit_delay Nonnegative duration string No 0ns Continuous exit-condition wait; zero clears immediately.

Numeric thresholds must be finite: NaN and Infinity are invalid. Durations support ns, us, ms, and s, such as 200ms. See configuration conventions.

Role requirements

Each mapping value is a string containing an existing signal name, such as current: pack_current. Roles select declared signals; they do not introduce extra input columns.

Preset Role When required Signal requirements semantic_id for automatic lookup
charge_session mode Always int64 or uint64; unit "1" battery.mode
charge_session current Always float64; A; sign_convention: positive_is_charge; measurement_location: pack_terminal battery.current
charge_session voltage When compute_energy is true; an explicitly supplied binding is checked even otherwise float64; V; measurement_location: pack_terminal battery.voltage
fault_context alarm Always bool; unit "1" fault.alarm
command_response request Always bool; unit "1" command.request
command_response response Always bool; unit "1" command.response
threshold_excursion signal Explicit mapping required int64, uint64, or float64; unit equals parameters.unit No automatic lookup

Automatic lookup also requires semantic_contract_version: "1". Explicit bindings need neither semantic field but still undergo type, unit, and other role checks.

Every role signal requires a positive resolvable validity duration and backward_hold. Explicit valid_for takes precedence; otherwise it is three times that signal's period or its DBC message period. Each role resolves its own period, not the driver's. If held values are needed and no period is available, supply validity explicitly. The latest valid value is held until valid_for expires. Missing, nonfinite, and out-of-range values remain subject to quality checks; presets cannot bypass them.

positive_is_charge means positive current is charging; pack_terminal means measured at the battery pack terminals. If charging current is negative in the device, explicitly preprocess it into a charging-positive input before binding and declaring this convention. The public signal conversion currently rejects A → A with scale: -1; changing only the label does not negate values. See conversion limits. Declarations do not replace checking actual wiring, calibration, and units.

When to provide semantic declarations

Use semantic_id semantic_contract_version Other requirements
Ordinary rules/calculations Optional Optional Expressions refer to name.
Explicit preset role_bindings Optional Optional Still meet role type, unit, direction, location, and validity requirements.
Omitted role, resolved automatically Role-specific string from the table, such as command.request String "1" from this release's role definition Exactly one signal must satisfy all requirements; zero or multiple candidates raise PlanValidationError.
threshold_excursion Not used for role lookup Not used for role lookup Explicit signal role required.

For automatic request/response lookup, add semantic_id: command.request and semantic_contract_version: "1" to the request signal, and command.response / "1" to the response. These select version 1 of those role contracts. The file still uses config_version: 4, while an omitted preset version defaults to "1"; the three version fields describe different objects.

Optional semantic text on original signals may be omitted or null. If semantic_contract_version is provided, semantic_id must also be provided. Optional semantic text on derived must be omitted or nonempty, not null. Derived semantic declarations describe results but do not make them candidates for preset roles in this release. Explicit role bindings also select only original signals. See derived fields.

Preset examples

Request/response example

Parameter reference.

Add or replace the root presets section in electrical-base.yaml. This fragment includes its parent key; do not place that key inside the preset list.

yaml
presets:                           # Predefined combinations of analysis nodes.
  - name: cmd                      # Prefix for generated node names.
    role_bindings:                 # Select existing signals for each role.
      request: request             # Previously defined boolean request.
      response: response           # Previously defined boolean response.
    parameters:                    # Parameters for command_response.
      max_delay: 2s                # Inclusive maximum response delay.
    preset_type: command_response  # Request/response preset.

This generates cmd_request, cmd_response, and cmd_pair. Setting emit_initial: true permits initially true values on both ends. Do not define ordinary rules with those same names. See sequences for pairing and missing data.

Threshold alarms and total duration

Parameter reference.

Add or replace the root presets section in the electrical base:

yaml
presets:                              # Predefined analysis nodes.
  - name: hot                         # Prefix for generated names.
    role_bindings:                    # Explicit signal selection is required here.
      signal: temperature             # Previously defined numeric signal.
    parameters:                       # Threshold and recovery requirements.
      enter_threshold: 80             # Enter at or above 80.
      exit_threshold: 75              # Clear at or below 75.
    preset_type: threshold_excursion  # Hysteresis alarm preset.

This preset always means value >= upper threshold to enter and <= lower threshold to exit. Entry must be strictly above exit. For a low-value alarm, write custom hysteresis conditions. This example uses degC for both input and analysis. You can convert a signal using registered unit relationships, such as degC to K. Preset thresholds must then use the converted signal unit and values, not the original Celsius numbers.

It generates hot_activity and hot_duration. Read per-activity durations through iter_calculations(). The total is in result.metadata.threshold_durations, or run.threshold_durations in the published run_manifest_<timestamp>.json. The public summary uses value and unit, with unit always s; it does not duplicate the duration in nanoseconds.

Observation Total-duration result Reason
85 for 3 s, 77 for 6 s, then clears at 75 9 s, complete Alarm state is known throughout.
Two alarms lasting 2 and 4 s with complete normal data between 6 s, complete Sum the two activities, excluding the gap.
Known non-alarm throughout 0 s, complete No alarm was observed.
First 3 s at 77, then 85 until 9 s value=6, unit=s, status=partial Initial state is unknown; only six known alarm seconds are counted.
Only 77 throughout, with no preceding known state None, indeterminate Unknown is not zero.
No valid observation interval, such as a single isolated timestamp None, no_observation There is no duration to summarize.

For nine observed seconds with the first three unknown and the last six definitely in alarm, the public summary has five fields:

Field Example Meaning
preset_id hot Preset instance producing the summary.
rule_id hot_activity Generated activity rule.
value 6.0 Known accumulated alarm seconds, not a complete total for all nine seconds.
unit s Unit of value, always seconds.
status partial Some intervals are unknown; retain this status when reading the value.

Ordinary calculation partial_policy and the preset total summary are separate interfaces. Lower-level fields such as known_active_duration_ns are not fields of this public summary. In preset-threshold-partial.yaml, 77 during 0–1 s leaves the preceding alarm state unknown, while 1–3 s is known alarm: value=2.0, status=partial.

A confirmation wait can also make the initial state unknown. In preset-threshold-delay.yaml, exit_delay is 500 ms: the initial 70°C does not establish a confirmed non-alarm state until 0.5 s. The activity [1.5,3.5) is complete and its per-activity result is 2 s / complete, but the session total is 2 s / partial because the first 0.5 s is unknown. These statuses describe different ranges.

The summary covers actual observation. If analysis requests through 12 s but the log ends at 9 s, also inspect the manifest's observed range. The summary does not prove there was no alarm during 9–12 s.

Charging activities and energy example

Parameter reference.

The charging preset below requires mode 1, current strictly above 5 A, and a continuous duration of at least 3 s, and calculates voltage × current energy. Replace the electrical base's root presets section:

yaml
presets:                         # Predefined analysis nodes.
  - name: charge                 # Prefix for generated names.
    role_bindings:               # Existing signals fulfilling the role requirements.
      mode: mode                 # Integer charging-mode signal.
      current: current           # Current in A, charging-positive at pack terminals.
      voltage: voltage           # Voltage in V at pack terminals.
    parameters:                  # Charging requirements.
      mode_value: 1              # Device's charging-mode code.
      current_min: 5             # Strict lower current threshold in A.
      minimum_duration: 3s       # Minimum continuous qualifying duration.
      compute_energy: true       # Generate power and Wh energy calculation.
    preset_type: charge_session  # Charging-period preset.

Fault-context window example

Parameter reference.

fault_context instead selects data around fault onset. A fault at 10 s with pre: 2s and post: 3s selects 8–13 s. If the log does not cover that entire range, results describe the observed portion. It does not measure the duration of the fault; use condition_duration or hysteresis for that.

See presets and preset models for lower-level types and generated fields (Chinese implementation references). Complete runnable inputs are linked from examples.

Chronaxis user manual · Offline edition